Galvanized rigid spiral pipe, 1 meter 500

  • On sale!
Galvanized duct for a ventilation system
Rigid, spiral-wound galvanized steel duct for ventilation and exhaust
Rigid Ducting for Mechanical Ventilation Systems in Professional Food Service Establishments
Galvanized rigid spiral pipe, 1 meter 500, vue 4
Galvanized rigid spiral pipe, 1 meter 500, vue 5
Galvanized rigid spiral pipe, 1 meter 500, vue 6
Galvanized rigid spiral pipe, 1 meter 500, vue 7
Galvanized duct for a ventilation system
Rigid, spiral-wound galvanized steel duct for ventilation and exhaust
Rigid Ducting for Mechanical Ventilation Systems in Professional Food Service Establishments
Galvanized rigid spiral pipe, 1 meter 500, vue 4
Galvanized rigid spiral pipe, 1 meter 500, vue 5
Galvanized rigid spiral pipe, 1 meter 500, vue 6
Galvanized rigid spiral pipe, 1 meter 500, vue 7

The galvanized rigid spiral duct in 500mm diameter and 1 metre length fits your extraction ductwork for mechanical ventilation or commercial kitchen hood systems with a sturdy section, ready to connect on the female end.

  • Diameter: 500mm
  • Length: 1000mm
  • Connection: female end
  • Operating temperature: -30°C to +250°C
  • Fire rating: A1
Last items in stock
Quantity
35.00 75.00 Tax excluded
42 € TTC
Last items in stock

Fast delivery
Advisers 5 days a week
Payment in 3 or 4 instalments
 

The galvanized rigid spiral duct is a galvanized steel ductwork section designed for extraction ductwork, whether for a professional mechanical ventilation system or a commercial kitchen hood installation. It measures 500mm in diameter by 1000mm in length, with a female end ready to take your fittings.

Technical specifications of the 500mm galvanized duct

Specification Value
Dimensions Length 1000mm
Diameter 500mm
Connection type Female end
Operating temperature -30°C to +250°C
Fire rating A1
Weight 22 kg

Use and compatibility

This galvanized duct suits any ventilation network that requires a rigid, durable duct: commercial kitchen hood extraction, commercial or communal mechanical ventilation systems, plant rooms. The galvanized steel handles everyday temperature swings in kitchens or workshops without issue, from -30°C to +250°C. The female end connects with male fittings of the same diameter: elbows, tees, or another duct section via a dedicated coupling.

Installation and connection

To join two duct lengths or connect this section to an elbow, use a suitable fixing and sealing kit: coupling, clamp and gasket ensure an airtight, well-secured network, with no air leaks or pressure loss at the joints. Aluminium foil tape finishes off the sealing at connection points.

Points to check before ordering

  • Check that the 500mm diameter matches your existing ductwork or your hood outlet, diameters are not interchangeable between ranges.
  • Count the number of lengths needed based on the total distance between the hood (or extraction point) and the discharge point.
  • Plan for connection accessories (male coupling, clamp, gasket) at each joint between two sections.
  • Keep in mind that transporting galvanized sheet metal can cause slight deformation at the ends: a moderate bend reshapes easily and does not create pressure loss in the network.
  • Make sure the 500mm diameter footprint fits within the available space (suspended ceiling, service duct, riser).

Goes well with

Also check out other diameters in the same range: 560mm galvanized rigid spiral duct, 630mm, 710mm or 800mm, as well as the standard 1 metre version and the 2 metre duct to reduce the number of joints on a long run.

Important note: supplied as single-piece ducts of 1 to 3 m depending on the quantity ordered. Transport of galvanized ductwork can sometimes cause deformation of the sheet metal, particularly at the ends: a perfectly smooth length is almost impossible to achieve. As long as the bends remain moderate, the section is not to be rejected, the ends reshape easily and a small dent does not cause pressure loss. Only a length that is completely crushed or folded over on itself will be considered non-conforming.

Product Details

Ventilsogood
conduit1ml500
Products
Sheath/Conduit
0657968262966

You might also like

8 other products in the same category:

Frequently asked questions

Which duct diameter should I choose for my ductwork?

The diameter must match your hood outlet or existing ductwork: this duct is available in 500mm. Measure the diameter of your existing installation or extraction point before ordering, as female ends only fit male fittings of the same diameter.

How do I connect two duct lengths together?

Use a male galvanized coupling between the two ducts, together with an insulated fixing clamp and a sealant gasket cartridge. This assembly ensures an airtight joint, with no air leaks or pressure loss in the network.

Can the duct withstand the heat from a kitchen extraction system?

Yes, this galvanized rigid spiral duct is designed for use from -30°C to +250°C, which covers the typical needs of commercial kitchen hood extraction or mechanical ventilation systems. Its A1 fire rating complements this thermal resistance.

Why is the duct sometimes supplied with slightly deformed ends?

Transporting galvanized sheet metal can cause minor deformation, particularly at the ends: this is almost unavoidable with this type of product. As long as the bend remains moderate, it reshapes easily by hand and does not create pressure loss in the network. Only a completely crushed length is considered non-conforming.