Rigid galvanized steel pipe, 1 meter
The rigid galvanized steel duct, length 1000 mm, is a robust solution for connecting your mechanical ventilation or commercial kitchen hood extraction system without having to cut down a longer duct.
- Length: 1000 mm
- Diameter options: from 80 to 630 mm depending on variant
- Female end
- Operating temperature: -30°C to +250°C
- Fire rating A1
Fast delivery
Advisers 5 days a week
Payment in 3 or 4 instalments
Rigid galvanized steel duct 1 metre, ventilation duct for mechanical ventilation systems and commercial kitchen hoods
The rigid galvanized steel duct is a 1000 mm long spiral duct, designed for professional mechanical ventilation extraction systems or commercial kitchen hoods. Its compact 1 metre format is particularly practical in tight spaces or for indoor installation work, without having to cut down a longer duct.
Technical specifications
| Specification | Value |
|---|---|
| Length | 1000 mm |
| Diameter | options from 80 to 630 mm depending on variant |
| Connection | female end |
| Operating temperature | -30°C to +250°C |
| Fire rating | A1 |
| Material | spiral galvanized steel |
| Weight | 8 kg |
Use and compatibility
This galvanized duct can be installed in any extraction system connected to a double-inlet centrifugal fan, an extraction fan box or a roof extract fan. Galvanized steel holds up well against grease and heat in a commercial kitchen (restaurant, fast-food outlet, kebab shop, snack bar, pancake house, brasserie), and steel remains non-combustible, a real advantage compared with flexible ducting on this point. The smooth internal surface limits pressure losses and lets air flow without putting extra strain on the fan motor.
Installation and connection
The duct connects using a suitable fixing and sealing kit, to be purchased separately. It can be cut to the required size or joined to other sections to suit the layout of your system.
IMPORTANT NOTE: the duct is supplied in one-piece lengths of 1 to 3 m depending on the quantity ordered. Transport of galvanized ducts can cause dents in the sheet metal, particularly at the ends: it is almost impossible to receive a length in perfect condition. Where dents are minor, there is no need to reject the product: the ends reshape easily, and a minor dent does not cause pressure loss in the system. Unless a length is completely crushed or folded over on itself, the goods are considered compliant.
Find all related accessories at the bottom of the page!
Points to check before ordering
- The diameter required for your hood or mechanical ventilation system's airflow: as a guide, Ø160 corresponds to approximately 800 m³/h and Ø200 to approximately 1200 m³/h, to be adjusted according to the pressure losses in your system.
- The total length actually needed: a 1 m format suits a one-off adjustment, while longer runs are usually made up of several ducts or 2 m lengths.
- The connection direction (female end) for assembly with your other system components.
- Compatibility with your existing double-inlet centrifugal fan, extraction fan box or roof extract fan.
- The need for a fixing and sealing kit, not supplied with the duct.
Recommended with
You might also like
8 other products in the same category:
Customers who bought this product also bought:
Frequently asked questions
What diameter of galvanized duct should I choose based on my hood's airflow?
The diameter depends on the target airflow of your system. As a guide only, and depending on the system: Ø160 mm for approximately 800 m³/h, Ø200 mm for approximately 1200 m³/h, Ø250 mm for approximately 1800 m³/h. These figures should be adjusted to account for pressure losses, elbows and the overall length of your installation.
Is the rigid galvanized duct compatible with a double-inlet centrifugal fan or an extraction fan box?
Yes, this rigid galvanized steel duct can be fitted into extraction systems connected to a double-inlet centrifugal fan, an extraction fan box or a roof extract fan, provided you select the diameter suited to your installation.
Is the 1 metre format enough, or should I order a longer length?
The 1 metre format is suitable for a one-off adjustment or a tight space. For a longer run, you can join several 1 metre ducts together, or choose a 2 metre rigid galvanized steel duct directly.
Why does the duct I received sometimes have slight dents?
Transport of galvanized steel ducts often causes dents in the sheet metal, particularly at the ends. It is almost impossible to receive a length in perfect condition. When dents are minor, they reshape easily and do not cause pressure loss in the system: the product remains compliant unless it is completely crushed.
How do I connect the rigid galvanized duct without losing airtightness?
The duct has a female end and connects using a suitable fixing and sealing kit, to be purchased separately. A male galvanized connector, an insulated fixing clamp and a sealant cartridge help ensure an airtight assembly with your other system components. See our tutorials on YouTube: https://www.youtube.com/@ventilsogood-cee