The 2-in-1 Roof Flashing and Cowl combines the roof penetration flashing and the rain cap into a single unit: discreet, neat, and quick to fit, it saves you from calling out a roofer for a weathertight outlet for your ventilation duct.

  • Diameter: choice of 125 to 630 mm
  • Material: pre-lacquered aluminium rain cap, tile red RAL 8004
  • Weatherproofing: soft lead flashing that follows the roof pitch
  • Compatibility: tile, slate, profiled steel sheet or corrugated sheet roofs
  • Protection: 2 side outlets fitted with pest-proof grilles
Diameter
In stock
Quantity
69.00 Tax excluded
82,8 € TTC
In stock

Fast delivery
Advisers 5 days a week
Payment in 3 or 4 instalments
 

The 2-in-1 Roof Flashing and Cowl is a pre-lacquered metal roof outlet that combines the penetration flashing and the rain cap in a single unit, for the exhaust or intake air of a roof-mounted ventilation system. Available in diameters from 125 to 630 mm, it blends into the roof covering thanks to its tile red RAL 8004 finish.

A single product for the roof penetration and duct protection

No more juggling several separate parts: this roof cowl acts as both the roof penetration flashing and the protective cap. The support plate, fitted beneath the flashing, is fixed directly to the roof structure using pre-drilled fixing holes (from Ø200 to Ø630 mm). Above it, the soft lead sheet follows the contours of the roof to ensure weathertightness, and the pre-lacquered aluminium rain cap closes off the assembly with its 2 side outlets protected by guard grilles. These grilles keep rodents and birds out of your ventilation system, a point that's often overlooked but which prevents a lot of unpleasant surprises. The connecting duct is made of galvanised steel, for a solid link to your existing ductwork.

Compatible with most roof coverings

This 2-in-1 roof cowl suits tile and slate roofs alike, and can also be fitted on profiled steel sheet or corrugated sheet roofing. The standard finish is tile red, but the cap can be repainted to better match a different coloured roof covering, particularly on a slate or profiled steel sheet roof where the original finish may not be suitable as is.

Technical specifications

Specification Value
Available diameter 125, 160, 200, 250, 315, 355, 400, 450, 500, 630 mm
Cap material Pre-lacquered aluminium, with guard grille
Weatherproofing Soft lead flashing
Support plate Fixing holes for roof structure (Ø200 to Ø630 mm)
Connecting duct Galvanised steel
Colour Tile red RAL 8004 (can be repainted)
Roof compatibility Tile, slate, profiled steel sheet, corrugated sheet
Fixing Self-drilling screws, sealing gasket and/or tape
Protection 2 side outlets with pest-proof grilles
Application Exhaust or intake air for ventilation systems
Weight 15 kg
Warranty 1 year

Installation and connection: quick fitting, no roofer needed

Fitting is done onto the roof structure, via the support plate fitted with fixing holes (available from Ø200 to Ø630 mm): no special tools required. The 2-in-1 design makes installation quick and simple, and often saves you from calling out a roofer for the roof penetration work. The malleable lead sheet can be shaped by hand to follow the pitch and contours of your roof (add a sealing mastic to reinforce weathertightness). The connection to the ventilation duct is then made with self-drilling screws, completed with a sealing gasket or tape, for an airtight joint.

Points to check before ordering

  • The diameter of your ventilation duct, to choose the cowl in the correct size from the 10 diameters available
  • The type of roof covering (tile, slate, profiled steel sheet, corrugated sheet) and the pitch, to check that the lead sheet will follow it properly
  • The space available on the roof around the planned outlet point
  • The colour finish required: the cap is supplied in tile red RAL 8004 finish, but can be repainted if needed

Goes well with

To complete your ventilation ductwork up to the roof outlet, see our 2-metre rigid galvanised steel duct, the female galvanised coupling to join your duct sections, or the 6 to 10 m fixing kit to secure your whole installation.

Product Details

Ventilsogood
chapeau2en1
Diameter
Products
Hat
Products
Outdoor Outings
Warranty
1 year
Package weight
5 kg
0657968636385

You might also like

8 other products in the same category:

Customers who bought this product also bought:

Frequently asked questions

What's the difference between a standard tile vent and this 2-in-1 roof flashing and cowl?

Unlike a standard tile vent, which only handles the duct penetration, this 2-in-1 cowl combines the roof penetration (support plate and lead flashing) with the protective rain cap and its pest-proof grilles, all in one unit. This saves you from fitting several separate parts during installation.

Which cowl diameter should I choose for my ventilation duct?

The cowl should be chosen to match the exact diameter of your ventilation duct. This model is available in 125, 160, 200, 250, 315, 355, 400, 450, 500 and 630 mm. Add a flexible connector to simplify the connection to the rigid duct if needed.

Is this cowl compatible with a slate or profiled steel sheet roof?

Yes, this 2-in-1 roof flashing and cowl is compatible with tile and slate roofs, as well as profiled steel sheet or corrugated sheet roofing (adapt the fitting for the latter two). The standard finish is tile red RAL 8004, but the cap can be repainted to better match a different roof covering.

Do I need a roofer to fit this roof cowl?

The 2-in-1 design makes fitting quick and simple, with no special tools needed in most cases. It's advisable to reinforce weathertightness, especially at the bottom of the pitch, and on the other sides with a sealing mastic if needed. This cowl often saves you from calling out a roofer. For any work at height, take care and use suitable equipment for your roof configuration.