Roof fan T40 exhaust fan - 4,200 m³/h - 230 V - 400°/2h

thf tvf 3640 saftair
Roof turret dimensions
Roof fan T40 exhaust fan - 4,200 m³/h - 230 V - 400°/2h, vue 3
roof extractor curve ventil.fr
Roof fan T40 exhaust fan - 4,200 m³/h - 230 V - 400°/2h, vue 5
ventilation system diagram
Roof fan T40 exhaust fan - 4,200 m³/h - 230 V - 400°/2h, vue 7
front-mounted or roof-mounted unit for a commercial ventilation system
Video
Video
thf tvf 3640 saftair
Roof turret dimensions
Roof fan T40 exhaust fan - 4,200 m³/h - 230 V - 400°/2h, vue 3
roof extractor curve ventil.fr
Roof fan T40 exhaust fan - 4,200 m³/h - 230 V - 400°/2h, vue 5
ventilation system diagram
Roof fan T40 exhaust fan - 4,200 m³/h - 230 V - 400°/2h, vue 7
front-mounted or roof-mounted unit for a commercial ventilation system

Roof fan Saftair horizontal exhaust system for ventilation, restaurant range hoods 

This exhaust turret is perfectly suited for professional range hoods measuring 3 to 5.5 m (3 to 6 filters) depending on the ductwork system, with 355 or 400 ducting.

- Capacity: 4,200 m³/h - 370 W - 0.68 A
- Power supply: 220/230 V single-phase
- Frame dimensions: 550 × 550, height 566
- Protective and bird-proof mesh
- Wired proximity switch
- F400/120 smoke extraction certification (open kitchen over 20 kW)
- Made in France
- It is mandatory to install thermal protection suitable for the equipment
- Compatible with an 8A single-phase voltage regulator (see below)
- Equivalents: Alvène EMMOS, Saftair TH, France air SIMOUN, Vim TE or TC...
- Weight: 40 kg

1-year warranty, provided the unit is installed by a professional.

In stock
Quantity
853.00 Tax excluded
1023,6 € TTC
In stock

Fast delivery
Advisers 5 days a week
Payment in 3 or 4 instalments
 

Roof fan T40 Professional Exhaust Fan Saftair 4,200 m³/h - Horizontal-Discharge Roof Exhaust Fan for Restaurant Commercial Rang Hood

Discoverthe high-performance roof-mounted exhaust hood designed to remove smoke and odors from commercial kitchens. This single-phase ventilation hood combines efficiency, reliability, and durability for your restaurant.

Key benefits of the Ventilsogood T40 exhaust fan:

  • Proper sizing: extraction tower perfectly calibrated for professional stainless steel range hoods ranging from 2 to 3.5 linear meters
  • Optimal performance: powerful 370-watt motor providing an extraction flow rate of 4,200 m³/h
  • Made in France: high-quality ventilation unit guaranteeing durability and meticulous craftsmanship
  • Built-in protection: roof-mounted exhaust fan equipped with a bird-proof screen
  • Fire safety: F400/120-certified smoke exhaust unit (withstands 400°C for 2 hours) compliant with standards for professional kitchens
  • Flexible use: single-phase roof exhaust fan compatible with a variable-speed drive for adjusting airflow

Application and Installation

This horizontal-discharge roof hood is the ideal solution for extracting smoke and odors in food service establishments: restaurants, fast-food outlets, kebab shops, snack bars, creperies, and brasseries. Can be mounted on the roof or facade depending on your layout.

Roof fan A quiet and reliable extraction system, designed for continuous operation in demanding professional environments.

Available Accessories

Optimize your installation with our ventilation deflector and galvanized steel roof flashing Ventilsogood. Find all related products for a complete installation.

Product Details

SAFTAIR
T40mono
Manufacturing
Made in France
Warranty
1 year
Package weight
45 kg
Engine
Roof fan roof
Standard
C4/30
Food
230V Mono
Engine power
4,000 to 6,000 m³/h
New
0657968634923

You might also like

8 other products in the same category:

Customers who bought this product also bought:

Frequently asked questions

Will the T40 roof fan suit my restaurant hood?

The T40 roof fan is intended for stainless steel commercial kitchen hoods of 3 to 5 m, that is 3 to 6 filters depending on the ductwork, for ducting of Ø355 or Ø400. This guide figure may need adjusting according to duct length, number of elbows and make-up air supply. To confirm the sizing, send us your hood dimensions, cooking power and a plan or photos of the ductwork.

What is the difference between horizontal and vertical discharge?

The T40 roof fan is designed for horizontal discharge, suited to roof or facade mounting. A vertical deflector kit is available as an accessory to direct the discharge upwards depending on the roof configuration or neighbouring constraints.

Which speed controller should be used with the T40 roof fan?

The T40 roof fan, supplied in 230 V single phase, is compatible with a single-phase fan speed controller. The controller must be sized according to the actual current draw of the fan to avoid any trip or fault.

What happens if the fan stops after a few minutes of operation?

A shutdown after 10 to 15 minutes can indicate that a thermal protection has tripped. Check for overpressure in the ductwork, the condition of the duct, the presence of sufficient air inlet and the electrical supply before putting the fan back into service.

What is the service life of the T40 roof fan?

The T40 roof fan carries a 1 year warranty, but its actual service life in building ventilation applications well exceeds 5 years, and often reaches over 10 years. Saftair has been manufacturing this type of roof fan for over 40 years in Normandy, evolving the model in line with standards and technical progress without ever compromising on reliability.

Is thermal protection mandatory with this fan?

Yes, thermal protection suited to the equipment is mandatory. Electrical connections must be carried out by a qualified electrician, which is a condition for the 1 year warranty to apply.