Nather C4 400°/ 1/2H 900 m³/h Enclosure

C4 F400° 1/2h VMC exhaust unit with smoke extraction capacity of 900 m³/h
Nather C4 400°/ 1/2H 900 m³/h Enclosure, vue 2
C4 F400° 1/2h Mechanical Ventilation System (VMC) Exhaust Unit with Smoke Exhaust Capability of 900 m³/h—Technical Information
C4 F400° 1/2h Mechanical Ventilation System (VMC) Exhaust Unit with Smoke Exhaust Capability of 900 m³/h—Technical Information
C4 Unit, 800 m³/h, for Extraction or Supply Air—Performance Curve
C4 VMC unit for exhaust or supply ventilation
C4 F400° 1/2h VMC exhaust unit with smoke extraction capacity of 900 m³/h
Nather C4 400°/ 1/2H 900 m³/h Enclosure, vue 2
C4 F400° 1/2h Mechanical Ventilation System (VMC) Exhaust Unit with Smoke Exhaust Capability of 900 m³/h—Technical Information
C4 F400° 1/2h Mechanical Ventilation System (VMC) Exhaust Unit with Smoke Exhaust Capability of 900 m³/h—Technical Information
C4 Unit, 800 m³/h, for Extraction or Supply Air—Performance Curve
C4 VMC unit for exhaust or supply ventilation

The Nather C4 900 m³/h extraction fan box provides extract or supply air in communal mechanical ventilation systems, built to the C4 400°C/30 min smoke extraction standard and running on a 230V single-phase supply. Supplied with a local isolator fitted.

  • Top of curve airflow: 900 m³/h
  • Power supply: 230V single-phase + earth
  • Recommended duct diameter: 250 mm
  • Smoke extraction standard: C4 400°C/30 min
  • Manufactured in: France
In stock
Quantity
627.00 637.00 Tax excluded
752,4 € TTC
In stock

Fast delivery
Advisers 5 days a week
Payment in 3 or 4 instalments
 

The Nather C4 400°/1/2H 900 m³/h Enclosure is a direct-drive motorised fan box designed for extract or supply air in communal and commercial mechanical ventilation systems. With a top of curve extraction volume of 900 m³/h, it covers the needs of a multi-occupancy residential building, a humidity-controlled system or a gas-ventilated installation.

C4 900 m3/h extraction fan box: which installations is it suited for?

This C4 extraction fan box is suited to ventilation systems in multi-occupancy residential buildings, whether humidity-controlled or connected to gas appliances, as well as commercial premises. The direct-drive fan unit operates at constant pressure, which limits electricity consumption over time. The optimal operating range is between 100 and 160 Pa.

Technical specifications

Specification Value
Reference caissonC4900
Brand Nather
Top of curve airflow 900 m³/h
Power supply 230V single-phase + earth
Standard Smoke extraction C4 (400°C/30 min)
Optimal operating range 100 to 160 Pa
Recommended duct diameter 250 mm
Spigots Circular 250 mm with lip seal
Enclosure material Galvanised steel
Manufactured in France
Warranty 1 year
Weight 25 kg

Installation and connection

The fan box is fitted with a cable grommet and a local isolator, pre-mounted and pre-wired, making maintenance work easier without having to open the main electrical panel. An access hatch to the motor allows for routine servicing. A bird/vermin guard protects the discharge outlet against pests entering the ductwork. The electrical connection must be carried out by a qualified professional, a condition required to maintain the warranty.

Points to check before ordering

  • The actual airflow required for your installation: as a guide, a 250 mm diameter is generally suited to an airflow in the region of 900 m³/h, but the ductwork (length, elbows, pressure losses) will affect the actual airflow achieved.
  • The type of mechanical ventilation system in your installation (constant extract, humidity-controlled or gas): check compatibility with your configuration before purchasing.
  • The safety standard required for your project: this fan box meets the C4 400°C/30 min standard, which should not be confused with an F400/120 classification (400°C/120 min), a different and more demanding requirement.
  • The size of the fan box: precise dimensions are available in the product photos, check these before installation in a suspended ceiling or plant room.
  • The power supply available on site: this model runs on 230V single-phase with earth.

To use alongside

Need a different airflow in the same range? Check out the Nather C4 500 m³/h fan box for smaller installations, or browse the full range of C4 motorised fan boxes to compare available airflows.

Product Details

Nather
caissonC4900
Manufacturing
Made in France
Warranty
1 year
Package weight
14 kg
Standard
C4/30
Food
230V Mono
Engine power
0 to 2,000 m³/h
0657968608573

You might also like

8 other products in the same category:

Frequently asked questions

What is the difference between a standard mechanical ventilation fan box and this C4 fan box?

A standard ventilation fan box cuts out or can melt under heat in the event of a fire. This Nather fan box meets the C4 smoke extraction standard, meaning it withstands 400°C for 30 minutes, allowing it to keep running during a fire in line with the requirements of this classification.

What duct diameter should be used with this 900 m3/h fan box?

The recommended duct diameter for this fan box is 250 mm, with circular spigots fitted with a lip seal. The optimal operating range is between 100 and 160 Pa: beyond this, pressure losses in the ductwork can reduce the actual airflow.

Does this fan box need to be installed by a professional?

VentilSoGood supplies this fan box but does not carry out the installation. The electrical connection must always be carried out by a qualified professional, a condition required to maintain the 1 year warranty. Fitting the fan box into the ductwork can be done by an installer or a building trades professional.

Is this C4 400°C/30 min fan box equivalent to an F400/120 classification?

No. The C4 standard for this fan box corresponds to resistance of 400°C for 30 minutes, whereas the F400/120 classification corresponds to 400°C for 120 minutes. These two fire safety standards are not interchangeable: check the exact requirement for your project before choosing.