The double-inlet centrifugal fan DDM 8/9 (Nicotra Regal) ref. 6N02T3 or E6G3501 is designed for stainless steel commercial extraction hoods, with an airflow of 3,000 m³/h on 230V single-phase. Made in Italy by Nicotra Regal, it replaces worn-out fans in restaurant, takeaway and catering kitchens.
Technical specifications of the 8/9, 9/9T, 9/9R double-inlet centrifugal fan
| Specification |
Value |
| Airflow |
3,000 m³/h |
| Power supply |
230V single-phase, 4-pole |
| Power |
420W |
| Current |
3.8A |
| Capacitor |
12.5 µF |
| Protection rating |
IP54 |
| Fan type |
Double-inlet, 8/9, 9/9T or 9/9R (same size and power) |
| Minimum hood height |
450 mm |
| Dimensions |
Outlet 30 x 26 cm, overall fan diameter approx. 33 cm (versus approx. 39 cm for a standard 9/9) |
| Weight |
11 kg |
| Package weight |
15 kg |
| Manufactured in |
Italy |
| Warranty |
1 year |
Fan 8/9, 9/9T or 9/9R: what is the difference?
The DDM 8/9 from Nicotra Regal (Italy), the CBM 9/9Tight from S&P (Spain) and the DARE 9/9R from CMC (Italy) share the same airflow of 3,000 m³/h and the same compact size, designed to fit hoods with a height of 450 mm or with a steep slope, with a diameter close to that of a 7/7 fan. If the Nicotra reference is out of stock, this fan is replaced by the CMC or S&P brand.
Compatibility and use
This centrifugal fan is suitable for stainless steel commercial hoods up to 3 metres in length and from 450 mm in height, used in restaurants, takeaways, fast-food outlets, pancake houses or catering kitchens for the extraction of smoke, grease laden vapour and cooking fumes. The mounting frame is included for installation in the hood or in an extraction fan box. This fan is not suitable for smoke extraction systems.
Connection is made in 230V single-phase. A single-phase fan speed controller can be added to adjust the airflow according to the ductwork and intended use.
Points to check before ordering
- Available height inside the hood: this fan is designed for configurations from 450 mm, but its compact size also makes it suitable for low or steeply sloped hoods.
- Diameter and length of the connecting duct: actual airflow depends on the ductwork (elbows, length, filters, air inlet), not just the maximum airflow of 3,000 m³/h.
- Presence of adequate air intake in the room: extraction without suitable make up air reduces actual airflow and can generate noise.
- Exact reference of the fan to be replaced (nameplate, photo) to confirm compatibility with this 8/9, 9/9T or 9/9R model.
- Whether a fan speed controller is needed: to be sized according to the fan current, which is 3.8A.
- Need for smoke extraction: this fan is not suitable for this use.