Roof fan T32 exhaust fan - 2,000 m³/h - 230 V - 400°/2h

Saftair TH2832 Turret
Assembly diagram for the Saftair Franceair Alvene Simoun turret
Roof fan T32 exhaust fan - 2,000 m³/h - 230 V - 400°/2h, vue 3
Saftair Simoun Franceair Turret
Roof fan T32 exhaust fan - 2,000 m³/h - 230 V - 400°/2h, vue 5
Dimensions of Roof Turrets Ventilsogood
Roof fan T32 exhaust fan - 2,000 m³/h - 230 V - 400°/2h, vue 7
Performance curve for the T2832 Saftair single-phase turret
Roof fan T32 exhaust fan - 2,000 m³/h - 230 V - 400°/2h
Saftair TH2832 Turret
Assembly diagram for the Saftair Franceair Alvene Simoun turret
Roof fan T32 exhaust fan - 2,000 m³/h - 230 V - 400°/2h, vue 3
Saftair Simoun Franceair Turret
Roof fan T32 exhaust fan - 2,000 m³/h - 230 V - 400°/2h, vue 5
Dimensions of Roof Turrets Ventilsogood
Roof fan T32 exhaust fan - 2,000 m³/h - 230 V - 400°/2h, vue 7
Performance curve for the T2832 Saftair single-phase turret
Roof fan T32 exhaust fan - 2,000 m³/h - 230 V - 400°/2h

Horizontal discharge roof extract fan for commercial kitchen hoods of 1 to 2 m, maximum airflow of 2,000 m³/h and single-phase 230 V motor, 250 W.

  • Maximum airflow: 2,000 m³/h
  • Power supply: 230 V single-phase
  • Motor power: 250 W (0.68 A)
  • Inlet diameter: 280 mm, recommended ducting Ø250 or Ø315 mm
  • Made in France, 1-year professional warranty
In stock
Quantity
559.00 639.00 Tax excluded
670,8 € TTC
In stock

Fast delivery
Advisers 5 days a week
Payment in 3 or 4 instalments
 

The T32 roof extract fan is a horizontal discharge roof fan designed for commercial kitchen hoods of 1 to 2 metres or for ventilating plant rooms, with a maximum airflow of 2,000 m³/h on a single-phase 230 V motor.

Roof fan 2,000 m³/h for commercial kitchen hoods or mechanical ventilation systems

This roof fan extracts smoke, steam and cooking odours out of the premises, with the motor located on the roof or facade. It is designed for stainless steel commercial hoods of 1 to 2 m, typically fitted with 2 to 3 filters.

Technical specifications

Specification Value
Maximum airflow 2,000 m³/h
Power supply 230 V single-phase
Motor power 250 W
Current 0.68 A
Motor 4 poles
Base frame dimensions 550 x 550 mm
Height 566 mm
Base inlet diameter 280 mm
Recommended ducting Ø250 or Ø315 mm
Weight 32 kg
Speed controller compatibility 5 A minimum
Manufacturing France
Warranty 1 year

Use and hood compatibility

The T32 roof fan is known for being quiet and is suitable for small restaurants, snack bars, fish and chip shops, or for mechanical ventilation of industrial premises. It is ideal for a hood measuring 1 to 2 m with 2 to 3 filters. The single-phase 230 V motor makes installation easier in premises without a three-phase supply.

It includes a bird protection guard and a factory-wired isolator switch mounted on the unit. Its speed can be adjusted using a single-phase speed controller rated at 5 A minimum, to match the extraction rate to kitchen usage.

Installation and connection

Connection is made to a Ø250 or Ø315 mm ductwork system, depending on duct length and number of elbows: a Ø315 mm diameter reduces pressure losses and noise on longer runs or those with several changes of direction. The larger the diameter, the better the airflow.

Installation requires correctly sized thermal overload protection suited to the motor, as well as a dedicated electrical supply line. VentilSoGood sells this roof fan but does not carry out installation: fitting and connection must be carried out by a qualified professional.

Points to check before ordering

  • Length of the hood and number of filters (2 to 3 filters for a hood of 1 to 2 m, as a guide).
  • Diameter and length of the existing ductwork, number of elbows: a Ø250 mm may become a limiting factor on a long run, while Ø315 mm reduces pressure losses.
  • Type of power supply available on site: this roof fan is single-phase 230 V, a three-phase version exists for 400 V installations.
  • Presence of a dedicated electrical line and thermal overload protection suited to the motor, a condition for the professional warranty.
  • Reference of the roof fan being replaced (Aldes Velone, Alvene EMMOS, France Air SIMOUN, VIM TEDH among others), to be compared specification by specification before ordering.

Recommended with

For a three-phase installation, see the T32 TRI roof extract fan, 2,000 m³/h. For a higher airflow, see the T25 roof fan, 2,500 m³/h 230 V. Browse the full range on our roof fans page.

Product Details

SAFTAIR
T32mono
Manufacturing
Made in France
Warranty
1 year
Package weight
25 kg
Engine
Roof fan roof
Standard
F400/120
Food
230V Mono
Engine power
0 to 2,000 m³/h
Engine power
2,000 to 4,000 m³/h
0657968848153

You might also like

8 other products in the same category:

Customers who bought this product also bought:

Frequently asked questions

What is the difference between the T32 roof fan in 230V single-phase and a three-phase version?

The T32 roof fan presented here runs on 230V single-phase, with a maximum airflow of 2,000 m³/h and a power of 250 W. It is suitable for premises without a three-phase supply. A three-phase version of the same model is available for installations with a 400V supply: the choice depends on the power supply available on site.

Which duct diameter should be used with the T32 roof fan?

The recommended ducting is Ø250 or Ø315 mm, to be chosen according to the length of the ductwork and the number of elbows. A Ø315 mm diameter reduces pressure losses and noise on longer runs or those with several changes of direction. The base inlet diameter is 280 mm.

Can the speed of the T32 roof fan be adjusted?

Yes, the T32 roof fan is compatible with a single-phase speed controller rated at least 5 A, to adjust the extraction rate according to kitchen or premises usage. It is also supplied with a factory-wired isolator switch mounted on the unit.

What are the conditions for the professional warranty on the T32 roof fan?

The T32 roof fan comes with a 1-year professional warranty, subject to installation by a qualified professional, the use of a dedicated electrical line and correctly sized thermal overload protection suited to the motor. Its observed service life is 7 to 10 years for catering use, and over 10 years for premises ventilation.

What hood size is the T32 roof fan suitable for?

The T32 roof fan, with its maximum airflow of 2,000 m³/h, is suitable for commercial kitchen hoods of 1 to 2 metres, typically fitted with 2 to 3 filters, as a guide. The airflow actually required also depends on the cooking power, duct length and number of elbows.