The Electronic variable speed drive ECO for Professional Restaurant Range Hoods is a single-phase 230 V voltage controller designed to drive a double-inlet centrifugal fan or small extraction fan box for a commercial kitchen hood, up to 4.5 A, with simple adjustment via potentiometer.
In a commercial kitchen, you don't run the extraction at full speed all day. Service peaks come and go, but between peaks, a motor running flat out consumes energy and makes noise for nothing. This ECO speed controller lets you reduce the motor's supply voltage to match actual use, while still giving you full control to increase power when the plancha or fryer are working hard. The ECO suffix here indicates good value for money within the range, while the Base version indicates compatibility with standard motors on the market.
Technical specifications of the ECO fan speed controller
| Specification |
Value |
| Reference |
Var4.5AECO |
| Brand |
Fasar |
| Controller type |
Voltage speed controller |
| Power supply |
230 V single phase |
| Maximum current |
4.5 A |
| Maximum power |
450 W |
| Manufactured in |
Europe (Italy) |
| Warranty |
1 year |
| Package weight |
500 g |
Which hood motor is this speed controller suitable for?
This voltage controller is designed for single-phase double-inlet centrifugal fans and small motorised fan boxes type 7/7, 7/9 or 8/9, with a rated current below 4.5 A. It features a speed adjustment potentiometer and an on/off switch, giving complete and immediate control over the motor. An output also allows you to connect a gas solenoid valve (GSV), useful for cutting off the gas supply if ventilation stops.
Please note: this speed controller is intended for single-phase 230 V use only. A three-phase 380/400 V motor requires a suitable variable frequency drive, not a voltage speed controller.
Installation and wiring
The speed controller is wired between the mains supply and the hood or extraction fan box motor. Electrical connection must be carried out by a qualified professional: this is in fact a condition for the warranty to apply in full.
Points to check before ordering
- Check your motor's rated current: it must be 4.5 A or lower, otherwise the speed controller will not hold the load over time.
- Confirm that your installation is indeed 230 V single phase: a three-phase motor is not compatible with this type of controller.
- If you need to control a gas solenoid valve, make sure its inrush current is compatible with the controller's GSV output.
- A motor that hums or struggles to start at very low speed is not necessarily a fault with the controller: stay within the adjustment range recommended in your motor's documentation.
To pair with
Need a different amperage or a smoke extraction function? Browse the full range in our single-phase 230V speed controller category.